The long-term operating temperature is 1200℃, with a maximum temperature up to 1250℃. Both the temperature control accuracy and the temperature field uniformity inside the furnace are ±1℃. It is compatible with 220V/380V voltage and supports multi-segment programming for temperature control. Specially designed to meet the high-temperature processing needs of various materials, it features stable and reliable performance.
Cooling Structure:Double-layer furnace shell, air cooling
Product Video
Applications:
Widely used in production and experiments in fields such as ceramics, metallurgy, electronics, glass, chemicals, machinery, refractory materials, new material development, special materials, and building materials.
Features:
Control accuracy: ±1℃; Furnace temperature uniformity: ±1℃ (varies according to the size of the heating chamber).
Easy operation: Programmable with PID self-tuning function, enabling automatic heating, automatic heat preservation, and automatic cooling, with no need for supervision. It can be optionally equipped with computer communication function, allowing operation of the electric furnace via computer (including starting/stopping the furnace, pausing heating, setting heating curves, storing heating curves, viewing historical curves, etc.). The software is free; for details, please refer to "Computer Control System".
Fast heating: The heating rate is adjustable from 1℃/h to 40℃/min.
Energy-saving: The furnace chamber is made of imported fiber, which is high-temperature resistant and can withstand rapid heating and cooling.
**The furnace body is finely spray-coated to resist corrosion and acid-alkali. The furnace body is isolated from the furnace chamber with air cooling, and the furnace wall temperature is close to room temperature.
Dual-loop protection: Protects against over-temperature, over-pressure, over-current, thermocouple breakage, power failure, etc.
**The furnace lining is made of imported refractory materials, featuring good heat preservation, high temperature resistance, and resistance to rapid heating and cooling.
Temperature categories: Five types available, including 1200℃, 1400℃, 1600℃, 1700℃, and 1800℃.
Maximum Temperature
1200℃
Voltage (AC)
220V/380V
Maximum Operating Temperature
1250℃
Long-term Operating Temperature
1200℃
Temperature Control Precision
±1℃
Temperature Field Uniformity in Furnace
±1℃ (depending on the size of the heating chamber); multi-point temperature control can be adopted for higher requirements
Temperature Measuring Element and Range
Nickel-chromium-nickel-silicon K-type, measuring range 0-1350℃
Number of Programming Curve Segments
50 segments for one group, 22 segments for two groups, 8 segments for three groups
Heating Rate
Adjustable from 1℃/h to 40℃/min
Heating Elements
Silicon carbide rods
Installation Position and Method of Heating Elements
Vertically installed on both sides of the furnace chamber
Refractory Materials
High-purity alumina fiberboard
Cooling Structure
Double-layer furnace shell, air cooling
Furnace Body Temperature
≤45℃
Computer Interfaces
RS485, RS232, USB
Warranty Scope and Period
The electric furnace is covered by a 1-year free warranty; heating elements are not covered (free replacement for natural damage within three months)
Random Spare Parts
2 heating elements, 2 sets of rod tools, 1 instruction manual, 1 certificate of conformity, 1 furnace door insulating brick, 1 pair of crucible tongs, 1 pair of high-temperature gloves
List of Optional Additional Functions
Name
Function Introduction
Function Code
Temperature Controller
Standard 50-segment heating curve, optional imported controller (B)
Choose one out of two.
AB
Touch Screen
Chinese menu, multi-curve storage, historical data recording (7-inch)
Choose one out of two.
C
IoT Interface
RS485 communication for real-time data access (start/pause/stop/curves/timing)
D
Computer Control System
PC software for full furnace control (start/stop/curve setting/data logging). Supports data recording (1s-1h intervals), parameter adjustment, and long-term storage.
E
PLC Control
Siemens PLC (controls heating curves, atmosphere, flow rates, power). Open ports for upstream/downstream equipment integration.
F
Observation Window
High-temperature quartz glass window on furnace door
H
Gas Inlet
Float flow meter + manual valve (selectable flow range/gas type)
Choose one out of two.
K
Digital mass flow controller (selectable flow range/gas type)
M
Exhaust
Manual exhaust valve
Choose one out of two.
T
Automatic electric valve (program-controlled by heating curve segments)
P
Full Auto Gas Control
PLC-controlled electric valves synchronized with heating curves (requires touch screen option)
Y
Casters
2 swivel + 2 fixed wheels
R
Rapid Cooling
Program-controlled cooling with inverter + centrifugal fan
N
Multi-zone Control
+10% cost per additional heating zone, +20% for independent control
X
Stirring Fan
Metal fan (<1050°C):-4000; Inverter: -1500-2000; PLC-auto control: -4000
Z
Separate Control Cabinet
Independent cabinet (1600×600×400mm) with 5m control cables
Q
Heat-storage Base
50mm recessed hollow base with multi-point support (+5% cost)
W
Exhaust Treatment
VOC treatment furnace (40m³/h or 80m³/h options)
V
Corrosion-resistant Chamber
Acid/alkali/HF-resistant materials
G
Heating Element Protection
Protective features against powder contamination and vapor corrosion
L
Clean Chamber
Ceramic/glass/metal lining to prevent dust/vapor contamination