| Temperature Grade | 1200℃ |
| Chamber Size | φ600mm × Depth 1000mm |
| Vacuum Degree | 10⁻³ Pa |
| Inner Vessel | 2 sets with lid, thickness 12mm; SUS310S, sealed type, removable at high temperature |
| Power Supply | AC 380V |
| Rated Working Temperature | 1200℃ |
| Long-term Service Temperature | 1150℃ |
| Temperature Control Range | 50~1200℃ |
| Gas Inlet | 1 pc |
| Temperature Sensor | Type K thermocouple, 0-1320℃, measuring inside inner vessel |
| Heating Element | High temperature alloy resistance wire |
| Heating Element Position | Arranged around chamber, protected by corundum-mullite |
| Heating Element Replacement | Integral hoisting, separate barrel cover after removing fasteners, restore after replacement |
| Temperature Control Accuracy | ±1℃ (Integrated circuit control, no overshoot) |
| Temperature Uniformity | ±1℃ (Subject to chamber size; multi-point control for large furnace for better uniformity) |
| Heating Rate | Adjustable; Max 20℃/min, Min 1℃/h |
| Furnace Body | CNC machined, polished, pickled, phosphated, powder coated and baked; Two-tone appearance, anti-oxidation, acid & alkali resistant, corrosion resistant, high temperature resistant, easy to clean |
| Furnace Structure | Double-layer air-cooled shell, combined air cooling + water cooling |
| Water Cooling Position | Furnace opening and furnace door |
| Vacuum Unit | Diffusion pump set, ultimate vacuum 6.6×10⁻⁴ Pa |
| Vacuum Gauge | Analog gauge (-0.1MPa), digital compound vacuum gauge, digital pressure gauge |
| Vacuum Pipeline | Complete gas circuit and valves |
| Pressure Rise Rate | 0.66Pa/h |
| Pressure Detection | Digital pressure detector |
| Mass Flow Meter | 1 digital mass flow meter |
| Pressure Protection | Signal from pressure gauge/sensor; auto close gas inlet, open exhaust valve, sound & light alarm for pressure relief |
| Available Atmosphere | Hydrogen, Nitrogen, Argon, CO, Oxygen, etc. |
| Refractory Lining | Vacuum formed high-purity lightweight alumina material; Light corundum-mullite for furnace opening & bottom; low heat storage, thermal shock resistance, no crack or slag falling |
| Insulation | Three-layer insulation: aluminosilicate fiber board, alumina fiber board, polycrystalline alumina fiber board |
| Shell Temperature | <45℃ under continuous non-stop operation |
| Protection Functions | Integrated control module, dual-loop control & protection; protection against overshoot, undershoot, thermocouple break, phase loss, overvoltage, overcurrent, overtemperature, current feedback, soft start |
| Control Mode | Closed-loop SCR control, phase-shift or zero-cross triggering; constant voltage / constant current / constant power with current limiting protection |
| Display Contents | Temperature, segment No., segment time, remaining time, output power %, voltage, current |
| Push Buttons | Imported buttons, service life>100,000 times with LED indicator |
| Temperature Controller | Intelligent controller with PID/APID/MPT, auto-tune & auto-learn, no overshoot; ramp/soak/cycle/pause, online modification, smooth curve fitting |
| Program Segments | 50-segment program control, multiple curves stored |
| Touch Screen | 7-inch touch screen |